Sarking and Wall Wrap: The Layer Most People Overlook

Sarking and Wall Wrap: The Layer Most People Overlook
In short

Sarking and wall wrap do more than keep rain out. How the reflective air gap works, why installation quality decides performance, and how it is modelled.

If you have read a NatHERS certificate or a list of BASIX commitments, you have probably seen a line about sarking or a reflective wall wrap and moved straight on to the insulation R-values. That line is doing more work than it looks.

Sarking and wall wrap are the thin membranes that sit behind cladding and under roof battens. They are inexpensive, they go on in a few hours, and they are one of the most commonly botched layers in a residential build. This post explains what they do, why a reflective foil is close to useless without an air gap, what goes wrong on site, and how the layer is treated in a thermal model.

What sarking and wall wrap actually do

Both products are pliable building membranes – flexible sheets stapled, draped or wrapped over the frame before the cladding or roofing goes on. Sarking is the term usually used for the roof membrane, and wall wrap is the same idea applied vertically. They do three separate jobs, and it helps to keep those jobs separate in your head, because a product that is excellent at one can be poor at another.

Secondary weather barrier. Cladding and roofing are the primary defence, but wind-driven rain gets past tile laps, behind weatherboards and through cladding joints. The membrane catches that water and drains it back out, away from the frame, the insulation and the internal linings. On exposed coastal and elevated sites this is the job that matters most.

Reflective air gap. Most Australian sarking has a foil face. Facing a still air gap, that low-emissivity surface cuts radiant heat transfer across the cavity. This is the part that shows up in the thermal calculation, and it is also the part most often defeated on site.

Draught control. A continuous, properly lapped membrane reduces uncontrolled air movement through the wall and roof. Air leakage is heat you paid to create escaping through gaps, and it is what the occupant feels as a cold draught at the skirting in July. As homes get better insulated, leakage becomes a larger share of the remaining heat loss.

Why the air gap is the whole trick

This is the part that gets lost in translation between the specification and the site. A reflective foil does not work by bouncing sunlight. It works because a bright metallic surface is reluctant to radiate heat, and radiant transfer only happens across a space. Remove the space and you remove the mechanism.

Press that foil hard against the back of the cladding, or staple it so tight that the bulk insulation squashes against it, and the foil becomes a thin sheet of metal in direct contact with the next layer. Heat conducts straight across it. The membrane still sheds water and still blocks draughts, but the reflective contribution the assessor entered into the model has effectively gone.

Dust matters too. A reflective surface facing upward in a roof space gradually collects dust, and dust radiates heat far more willingly than clean foil does.

The honest scale of the benefit is worth stating. A reflective air gap adds genuine thermal resistance, but it is a modest contribution compared with bulk insulation in the ceiling or walls. It is a useful addition to a good insulation strategy, not a substitute for one. If you want the detail on where the real resistance comes from, our guide to insulation R-values in NSW covers it.

Where each membrane belongs

Product selection depends on the roof or wall system, the climate zone and the cladding. The table below sets out the common options in NSW residential work.

Membrane Main jobs Typical use Watch for
Reflective foil roof sarking Weather barrier, reflective air gap, dust and draught control Under tiles or metal roofing over battens Needs a genuine air gap below the foil face, and support so it does not pond water
Vapour permeable wall wrap Weather barrier, draught control, lets vapour escape outward Timber and steel framed walls, lightweight cladding, cooler and mixed NSW climates Permeability is lost if it is buried behind a second impermeable layer
Reflective, low permeability wall wrap Weather barrier, reflective air gap, draught control Brick veneer cavities and some warm-climate walls Can trap moisture inside the wall if the layer order is wrong for the climate zone
Breather-type roof underlay Weather barrier plus outward vapour movement Lower pitch metal roofs and some skillion roofs Usually needs a drained and ventilated cavity to work as intended
No membrane None Rarely appropriate in new work Loses the weather barrier, the draught control and any modelled reflective benefit

Which membrane suits your wall is partly a moisture question rather than a heat question, and the two can pull in different directions. That trade-off sits alongside the heat flow work we do in a thermal performance assessment, and your certifier confirms the specific requirement that applies to your build.

What goes wrong on site

Membranes are installed early, covered immediately, and almost never inspected again. That combination makes them a reliable source of underperformance. The common failures are mundane:

  • Foil stapled so tight that an insulation batt compresses against it and closes the air gap.
  • Laps run the wrong way, so water drains behind the membrane rather than over it.
  • Tears around window openings, service penetrations and pipe entries left untaped.
  • Wrap stopped short at the bottom plate with no path for water to drain out.
  • Wrap cut back or removed by a later trade and never repaired.
  • A vapour permeable wrap specified, then a cheaper impermeable foil delivered to site and installed instead.

The last one is the costliest, because it changes the moisture behaviour of the whole wall and nobody notices until a lining stains years later.

How sarking is treated in a thermal model

In a NatHERS assessment the membrane is not a loose extra. It forms part of the defined construction for each wall, roof and ceiling element, and the modelled resistance depends on the surface emissivity, the width and orientation of the adjacent air gap, and the direction of heat flow. All four accredited tools – AccuRate, FirstRate5, BERS Pro and HERO – run the same CSIRO Chenath engine, so a correctly modelled house gets the same answer in any of them. Our assessors work in FirstRate5 and HERO.

Two practical consequences follow. First, if your plans and specification say reflective sarking with an air gap, the model assumes you built it that way. The software has no way of knowing the foil was squashed flat. Second, if the membrane is not nominated on the documentation, the assessor cannot assume it is there. We model what is specified, which is why the documentation you send us directly affects the result.

If a rating is sitting just short of target, upgrading the reflective layer is sometimes a sensible, low-cost adjustment. More often the bigger levers are ceiling insulation, glazing and shading, and we will tell you which one is actually moving the number.

Frequently asked questions

Is sarking required on every new home in NSW? Not universally. The requirement depends on the roof and wall system, the cladding, the climate zone and the condensation provisions that apply, and your certifier or council confirms it for your project. In practice most new NSW homes include a membrane in at least the roof.

Does wall wrap replace insulation? No. A reflective wrap facing an air gap adds a modest amount of thermal resistance. Bulk insulation in the ceiling and walls does the heavy lifting, and no membrane will compensate for an underinsulated ceiling.

Can I add sarking to an existing roof? Only by lifting the roofing, which makes it a re-roofing job rather than a standalone upgrade. If you are re-roofing anyway it is a cheap addition at that moment. For an existing home, topping up ceiling insulation almost always gives more comfort per dollar.

Will upgrading to a reflective wrap get me the extra half star? Sometimes, but do not count on it. It is worth testing in the model alongside glazing and shading changes before you commit. We run those comparisons as part of a NatHERS assessment so you can see which change earns its cost.

Planning a build in NSW? Send us your plans for a fixed-fee quote within one business day.

10 Tips for a 7-Star New Build

Our practical PDF guide to building a comfortable, compliant NSW home - the design decisions that matter most, and how to reach 7 stars without overspending.

We will only use your email to send the guide and the occasional useful update. Unsubscribe anytime. This form is protected by reCAPTCHA.

NathersPro
NathersPro

BASIX & NatHERS specialists helping NSW homeowners and builders achieve energy-efficient, compliant homes.

Related reading

Need this assessed for your project?

Send us your plans and we’ll return approval-ready documentation in 3-4 days - with 24-hour express available.

Chat with us